loading spinner

Top sellers

Information

VJT 2723C

VJT 2723C

New product

Refrigerator for labs and pharma; 141 l; glass door; adjustable temperature from 3°C to 16°C, div. 0,1°C; 3 shelves; alarms: under and over temperature, door open and power failure; remote alarm; lockable door. Suggested use: lab, drugs.

More details

Delivery in 15-20 Days

1 371,00 € tax excl.

Bonifico, Contrassegno, Carte di credito o Paypal
Bonifico, Contrassegno, Carte di credito o Paypal

Data sheet

Adjustable temperatures (°C)+3°C...+8°C
Exterior Dimensions mm WxDxH600x620x820
Inner Dimensions mm WxDxH440x440x670
Inner Gross/Net Capacity Liters141
Shelves / Baskets3
Inner FanYes, disconnectable
Control PanelDigital Display
Open door alarmYes
Power Failure AlarmYes - it last about 12 hrs.
Visual and acoustic temperature alarmYes - Min. & Max temperature
Adjustable alarmsYes
Remote alarmYes
Max Ambient Temp. to reach the Min. Temperature43
Data loggerAs an option
RS 485 InterfaceYes
LockYes
Inner LightYes
DefrostAutomatic
Porthole for PT 100Yes
Refrigeration technologyCompressor
Insulation mm40
Noise level (db)45
RefrigerantR600a
Climate ClassSN-ST
Energy consumption [kWh/24h]1,010
Connection rating (A)1
Supply Voltage (V) / Frequency (Hz)220 - 240 / 50
Weight kg37
Comply with Italian Republic Farmacopea Ufficiale XII edizione Tabella VIYes
VariousVentilato, memorie d'allarme con data e ora, termostato di sicurezza, chiusura porta automatica
WarrantyInternational Warranty 24 months only for spare parts.

More info

Laboratory refrigerators and/or for drugs. The digital display constantly monitors the internal temperature and reports any alarms. The last three alarms are stored by the system and retrieved on demand. Refrigerators powerful and well insulated thermally because suitable for ambient temperatures from 10 ° C to 38 ° C; housing in white painted steel; internal space in PS.

     Glass door;
     Electronic controller and digital display precision 0.1 ° C;
     Alarms: adjustable under and over temperature;
     door open alarm;
     blackout alarm;
     deactivated audible alarms;
     storing maximum and minimum temperature alarms;
     potential-free contacts for external alarms;
     temperature calibration;
     RS 485 interface;
     Safety thermostat to prevent freezing;
     lock;
     10mm hole insertion probes;
     Automatic defrosting;
     door on the right, reversible
     ventilated;
     Insulation: 40mm;
     Hole for inserting probes

Accessories